INVERTERS, UPS, BATTERIES,
R.O.SYSTEMS.
SALES & SERVICE
16/3 East Patel Nagar
New Delhi 110008
Everything in Inverters and batteries
The Inverter is installed on 5 amps Light circuit. We ensure that proper wires are used and a bypass system is provided. It comes in handy when there is a problem in the system.
Power appliances like fridge, geyser, motor etc are separated to avoid inconvenience in the long run.
We provide free service visits on request for one year from the date of purchase. Although we use ultra low maintenance batteries they do require periodic checking of water levels. Our suggestion is once every three Months. Our technicians also take rounds to check batteries but the responsibility of battery maintenance is with the customer.
We offer a wide variety of affordable maintenance options after the free service period of one year.
You can choose from
Battery only
Battery and Inverter ( without components )
Battery and Inverter ( all components included )
Replacement of old Inverter Battery with ultra low maintenance Inverter Battery.
Get additional benefits like free service visits and Inverter Warranty
INVERTER MAINTENANCE TIPS.
Ensure that the load connected to the Inverter is not more than the designated load of the inverter, for example a 1400VA Inverter should not have more than 1400X0.8 = 1120 Watts load attached to it.
Get your electrician to install a bypass system. In case of fault in Inverter like repeated blowing of fuse or tripping of MCB or sparking in Inverter etc, you can bypass the Inverter and call your dealer.
Keep your Inverter in a well ventilated place away from water and direct sunlight. There will be short circuit in the Inverter if water enters the circuit. Remember, any damage due to water entering the circuit is not covered in warranty or under AMC.
Dont keep any container having water or liquids like tea, milk etc on the Inverter. The Inverter should not be placed below an AC or cooler or near a tap.
Keep an eye on the charging Indicator, the Inverter should have a charging cut off, get your Inverter and Battery checked if the charging is being done continously.
Don't run your Inverter continously on full load. We recommend the running load to be around 60%or less of the full capacity for longer Battery backup and longer life of the system. Using electronic chokes on tube lights and Compact florescent lights you can get extended backup and better performance.
Avoid running inductive loads like motor and food processor etc on Inverter.